Products

EAC Ex Approved RTD Pt100 Sensors

with Pot Seal

Our EAC Ex approved flexible mineral insulated platinum resistance thermometers utilise, as standard, detector elements with a resistance of 100 ohms @ 0°C and a fundamental interval of 38.5 ohms to IEC 60751. Single and duplex elements are available. An adjustable threaded compression fitting is required to achieve approval.
  • Available in a wide range of protection concepts for Zones 0, 1 & 2 use. See table below for details
  • Temperature classification T6-T1, see here for stand-off requirements
  • Available in B, A, 1/3, 1/5 and 1/10 grade accuracies
  • Metrological / Pattern Approval Certificate (PAC) for Russia also available on request, contact us for details
  • Additional Primary verification “POVERKA” available on request, contact us for a quotation if required
  • Sheath diameters from 3.0mm to 8.0mm
  • PVC or PFA insulated extension cables are available or 100mm tails
  • Wide operating temperature range of -100°C to +600°C
  • UKAS calibration available.
Available with the following approvals:

Protection Type Description Zone
Ex d IIC Gb Flameproof (Gas) 1
Ex ia IIC Ga / IIIC Da Intrinsically Safe (Gas/Dust) 0/20
Ex tb IIIC Db Enclosure (Dust) 21
Ex tc IIIC Dc Enclosure (Dust) 22



Enquiry Form

1. No. of Elements


2. Protection Concept


Concept Type Select
Ex d Flameproof/Explosion Proof
Ex ia Intrinsically Safe
Ex tb Enclosure
Ex tc Enclosure

Your chosen concept is:


Ex d Flameproof/Explosion Proof – Category 2, Zones 1,2 (Gas)
• Ex d IIC T6...T1 Gb Ta = –40°C to 60°C
• Standard EN IEC 60079-1 refers
• Designed to contain an explosion and quench the flame
• Sensors incorporate a suitable heavy duty enclosure or threaded fitting with tight seals

Your chosen concept is:


Ex e Increased Safety – Category 2, Zones 1,2 (Gas)
• Ex e IIC T6...T1 Gb Ta = –40°C to 60°C
• Standard EN IEC 60079-7 refers
• Design ensures no arcs, sparks or hot surfaces that could ignite an explosive mixture with a minimum IP54 enclosure rating
• Sensors incorporate a suitable heavy duty enclosure or threaded fitting with tight seals

Your chosen concept is:


Ex ia Intrinsically Safe – Category 1, Zones 0,1,2 (Gas) & 20,21,22 (Dust)
• Ex ia IIC T6...T1 Ga Ta = –40°C to 60°C
• Standard EN IEC 60079-11 refers
• Designed to limit the energy of arcs or sparks that could potentially ignite an explosive mixture
• Sensors used in this area must be wired through a suitably approved barrier
• Optional approved 4 to 20mA transmitters available

Your chosen concept is:


Ex nA Non-Sparking – Category 3, Zone 2 (Gas)
• Ex nA IIC Gc T6…T2
• Standard EN IEC 60079-15 refers
• No arcs, sparks or hot surfaces

Your chosen concept is:


Ex tb Enclosure – Category 2, Zones 21, 22 (Dust)
• Ex tb IIIC T80°C…T440°C Db
• Standard EN IEC 60079-31 refers
• Protects against combustible and conductive dusts, rugged tight enclosures are used

Your chosen concept is:


Ex tc Non-Sparking – Category 3, Zone 22 (Dust)
• Ex tc IIIC T85°C...T450°C Dc
• Standard EN IEC 61241 refers
• Protects against combustible dusts
• Sensors incorporate a suitable heavy duty enclosure with IP6X seal

3. Number of Wires


4. Sheath Diameter


5. Sheath Length


 mm*

6. Tolerance of Element


Grade

Accuracy

@ 0ºC

Accuracy

@ 100ºC

Select
B +/- 0.30ºC +/- 0.80ºC
A +/- 0.15ºC +/- 0.35ºC
1/3 +/- 0.08ºC +/- 0.19ºC
1/5 +/- 0.05ºC +/- 0.15ºC
1/10 +/- 0.03ºC +/- 0.12ºC

7. Extension Leads


Illustration Select
PVC (rated to 105ºC)
End Seal rated to 120ºC
PFA (rated to 250ºC)
End Seal rated to 230ºC
Please enter Cable length in metres

 mtrs

8. Compression Fitting


9. Quantity Required


Contact Details


Company Name


Your Name


Email


Telephone


Additional Information


If your enquiry is for more than one style of sensor, please email us with your requirements or use the box below



Send Enquiry  
BACK TO TOP
EAC Ex Thermocouples with Pot Seal

EAC Ex Thermocouples with Die Cast Alloy Head

EAC Ex Thermocouples with Die Cast Alloy Head and Process Thread

EAC Ex Thermocouples with St./St. Head

EAC Ex Thermocouples with St./St. Head with Process Thread

EAC Ex Thermocouples with Dual Entry Head

EAC Ex Thermocouples with Dual Entry Head with Process Thread

EAC Ex Thermocouples with Spring Loaded Block

EAC Ex Thermocouples with Terminal Entry Gland

EAC Ex Thermocouples with Terminal Entry Gland with Process Thread

EAC Ex Spring Loaded Thermocouples

EAC Ex Thermocouple Feedthroughs
EAC Ex RTD Pt100 Sensors with Pot Seal

EAC Ex RTD Pt100 Sensors with Die Cast Alloy Head

EAC Ex RTD Pt100 Sensors with Die Cast Alloy Head with Process Thread

EAC Ex RTD Pt100 Sensors with St./St. Head

EAC Ex RTD Pt100 Sensors with St./St. Head with Process Thread

EAC Ex RTD Pt100 Sensors with Dual Entry Head

EAC Ex RTD Pt100 Sensors with Dual Entry Head with Process Thread

EAC Ex RTD Pt100 Sensors with Spring Loaded Block

EAC Ex RTD Pt100 Sensors with Terminal Entry Gland

EAC Ex RTD Pt100 Sensors Terminal Entry Gland with Process Thread

EAC Ex Spring Loaded RTD Pt100 Sensors
EAC Ex Pressure and Vacuum Feedthroughs



© 2014-TC Ltd., PO Box 130, UXBRIDGE UB8 2YS United Kingdom.
Tel.: 01895 252222, Fax: 01895 273540, Email: info@tc.co.uk







Wiring Diagram Sheath Materials

Assemblies with pot seals are supplied with short tails as shown. However, where leads are several metres or more long, it is more suitable to have an overall sheathed cable. We recommend the following cables.